1pcs 85L1 300mA AC Analog Ammeter Panel AMP Current Meter 0-300mA AC directly connect No need Shunt

USD 3.24USD 3.48

1pcs 85L1 300mA AC Analog Ammeter Panel AMP Current Meter 0-300mA AC directly connect No need Shunt

Description
Name: 85L1 sheet
Model: 85L1-300mA
Outer size: 65x55mm opening size 55x50mm
 
Main technical parameters
 
Name         common specification        remarks
AC ammeter A:0.5-50A         can be directly connected.
A:10/5A-800/5A       secondary current through current transformer
KA:1KA-10KA        secondary current through current transformer
AC voltmeter V:10V-600V       can be connected directly.
KV:1KV-35KV     through current transformer through secondary current 100V
DC ammeter A, mA:50, A-500, A 1mA-500mA    can be directly connected.
A:1A-15A    can be connected directly.
A:15A-750A    externally attached shunt 75mV
KA:1KA-3KA    externally attached shunt 75mV
DC voltmeter V:3V-600V     can be directly connected.
KV:1KV-3KV   external fixed value resistor
 
 Measurement range of current voltmeter
 
This series of products is suitable for measuring current and voltage in power frequency alternating current or direct current.
Structural features:
This series of products use magnetoelectric system internal magnetic structure when measuring DC; AC current, voltmeter is a DC head of internal magnetic structure, attached transistor rectifying circuit device, this device is attached to the meter table with backpack outside, and they are separated from the measuring mechanism in two rooms for maintenance. The cover of the meter housing is made of transparent plexiglass and white plastic.
Conditions of use:
-20 C ~50 C, relative humidity is less than 85% (25 C)
Main technical parameters
The technical specifications of this series of products are fully in line with GB/T676-1998. Technical requirements for direct acting analog indicating electrical measuring instruments and accessories.
The accuracy of the meter is grade 1.5 or 2.5.
Withstand voltage: withstand voltage of sinusoidal wave AC 50Hz, 2KV voltage, lasting one minute.
Damping time: less than 4 seconds
Working position: vertical use.
Direct measurement: 3V; 5V; 7.5V; 10V; 15V; 20V; 30V; 50V; 60V; 75V; 100V; 120V;
The limits of measurement are: 3.6KV; 7.2KV; 12KV; 18KV; 42KV; 15KV; 300KV; 460KV; 450KV; 600KV.
Mutual inductor ratio: 3KF/100V; 6KV/100V; 10KV/100V; 15KV/100V; 30KV/100V; 110KV/100V; 220KV/100V; 300KV/100V; 380KV/100V; 500KV/100V.
Measuring transformer ratio by mutual inductor: 5A/5A; 10A/5A; 15A/5A; 20A/5A; 30A/5A; 50/5A; 75/5A; 100A/5A; 150A/5A; 200A/5A; 250A/5A;
The current, voltage, power, power factor and frequency meter are magnetoelectric series instruments. It has the advantages of high sensitivity, low power consumption, uniform calibration and good damping. It mainly uses various high and low voltage switchgear, power supply cabinet, control cabinet and various electronic control devices to monitor circuit current, voltage, power, power factor and frequency. The performance of the product meets the standard of GB7676-1998. The main technical parameters: the accuracy is: 1.5 level use conditions: -20 ~ + 50 C, relative humidity less than 85% pressure resistance: self frequency variation of + 15%, the indication error does not exceed the basic error mechanical performance: can bear acceleration of 30 meters per second 2, the impact frequency 80-120 times per minute, two hours to transport the working position of earthquake: The structural features of vertical direction are: plastic, bakelite shell, glass window, magnetic structure in magnetoelectric system. The company specializes in the production of pointer type current voltmeter, power meter, power factor meter, frequency meter and other products.
 
 Scope of application
 
This series of products are two kinds of magnetoelectric system and electromagnetic system. It is suitable for the display panel and large switch board installed in the control system and distribution system, such as AC and DC current, voltage, power factor, power, synchronization value, frequency, unfolded voltage and overload electric current. The variation of the self frequency fixed value is + 15%, which causes the error of the indicator value not to exceed the basic error; the mechanical performance can be accelerated to 30 meters per second, the impact frequency is 80-120 times per minute, and the operation position is in two hours.
IMG_4721_1_ IMG_4700_ IMG_4704_ IMG_4705_1
IMG_4710_1
Specification

Operating Temperature : -20~50Centigrade

Supply Voltage : AC

DIY Supplies : ELECTRICAL

Model Number : 85L1 300mA

Display Type : Analog Only

Brand Name : LAOKE

Dimensions : 65mm*55mm

Accuracy Class : 1.5

+