5V Time Relay / Timing / Voltmeter Control Relay Switch / Cycle Start / Count Trigger

USD 9.10USD 10.00

5V Time Relay / Timing / Voltmeter Control Relay Switch / Cycle Start / Count Trigger

Description

 

Please read the instructions before using the wiring operation!Electronic manual download address:(copy URL to browser open)

Electronic version manual download address: http://pan.baidu.com/s/1ntA1ZWP

English version: http://pan.baidu.com/s/1gdy2X7H

 

Relay contact is equivalent to the switch, wiring should be connected in the power supply circuit load, the power supply can not be short circuit connection.The working power supply terminal uses the bolt type 5.08mm connection terminal, if your power plug is DC5.5-2.5 round hole type, you can use the adapterhttp://item.taobao.com/item.htm?spm=a1z10.1.4.23.5f2c50&id=14826309990

Mode display:

P-1: time relay (0.1 seconds to 99.9 seconds, the first attraction and then release)

P-2: time relay (1 to 999 seconds, 1 minutes ~ 999 minutes),First pull and release)

P-3: pulse counter (count to the set value when the pull or start timer)

P-4: voltage relay (voltage detection and control)

P-5: switch timing trigger (when the input switch or level timer to set the trigger)

P-6: digital tube display automatic shutdown settings (minimum operating current 6mA/12V)

Working power input: 5V DC; 12V power supply version please shoothttp://item.taobao.com/item.htm?id=13331293191

Timing range: can be switched by 0-999 seconds or 0-999 seconds, can be set up time and release time.

Voltage detection and display range: DC0-99.9V or 0-9.99V, the default delivery for DC0-99.9V hardware version

Relay parameters:

  • Coil input DC5V/12V/24V (5V power version with 5V relay)
  • A set of transformations (normally open and normally closed)
  • Contact load:10A/277VAC
  • Contact resistance: ≤ 100mΩ (1A-6VDC)
  • Mechanical durability: > 10 million times
  • Electrical durability: > 100 thousand times (10A-250VAC)
  • Working environment temperature: -40 ~ 85
  • External signal input: active (0-12V)
  • Passive switch capacity (can be set up 9 times to eliminate jitter time)
  • Mode setting parameters can be saved by power, the power to continue after the last mode.
  • Digital control module socket installation, can be directly removed.
  • Standby current: 16mA/12V, digital control offMinimum 6mA/12V
  • If the power supply is switched on in any mode, the system will continue to run in the last state after the power on again. The parameters can be saved by power down. In any mode, press the ENTER key for 3 seconds to return to the mode selection state.

 

P-1, P-2, P-3 mode, used as a time relay, time relay, counting relay application video:Control 220V AC bulb:http://www.tudou.com/programs/view/tSX091IGb3I/

Voltage relay:http://www.tudou.com/programs/view/D7zAOiEjvZI/

 

P-5 mode, switch timing trigger function demo video:http://www.tudou.com/programs/view/y6PJVrgwhcg/

 

 

 

P-1 mode,P-2 mode:Use of time relay or time relay

Timing range: P-1:0.1 ~ 99.9 seconds;

P-2:1 ~ 999 seconds or 1-999 minutes, switchable;Relay first pull and delay release.

Loop execution:

Time relay mode, the user can set the relay pull in time and release time of T1 T2, for example, set T1 to 3 seconds, T2 for 7 seconds, then the relay will run for 3 seconds and then pull the first 7 seconds of the release, so the cycle.

When you set the T1 and T2 time value, the system will power to save the set value, the next run will automatically load the T1 time to start running.

Single execution timing:

If only set T1 (pick-up time), T2 (release time) was 0, while the relay stops running T1 in the timing time, longer cycle operation, available at this time as a timer, T1 timing, the relay is released, then press the ENTER key, the system re start timing in T1 time.

If the T1 (pull time) is set to 0, the relay has been in a state of release (do not start running, normally closed point connected, normally open off).

Time relay mode, by pressing the ENTRE key, or the external switch / pulse input interface, can control the timing of the start or stop. At the time of operation, the external switch input will not affect the timing of the operation, the timing of the end, there is an external switch signal input will start the timer again.

The use of external trigger signal timing relay, a switch or external pulse signal (rising from the low level into a high level), if the input level remained unchanged (or switch does not move), will not trigger the timer.

 

 

P-3 mode: counting relay

For external pulse or switch volume counter, the maximum count value of 3999, and can be set to 9 external signal jitter delay value. The user can set the value of the relay action, when the external input count reaches the set value, the relay will be set according to the parameters such as execution time relay mode, you set a timer 2 seconds after the release of the time relay mode, then count to the set value, the relay will pull in 2 seconds to release, if time relay parameters are set to 0, then the count reached the set value of relay flip (release variable pull, pull in turn release).

P-4 mode: voltage relay

The use of voltage detection and control function can be set on the lower limit of voltage, voltage exceeds the upper limit of the relay by releasing into pull until the voltage is lower than the set lower limit value again release relay, this function can be used as DC voltage monitoring, voltage meter, voltage meter display range: default delivery error 0-99.9V, ± 0.1V.

Voltage detection range of 0-9.99V error ± 0.01V hardware version please note. In the P-4 mode long press SET button for three seconds after release, detection voltage control logic will take, you can select the voltage exceeds the upper limit relay, or below the lower limit voltage relay.

Voltage detection control mode demo video: http://www.tudou.com/programs/view/D7zAOiEjvZI/

 

 

 

P-5: switch timing trigger

Can be input to the outside of the switch or the level of timing (switch / pulse input terminal “ IN&rdquo), when the timer reaches the set value to start the timer or relay switch. Timing and P-2 mode T1, T2 for the same group, 1-999 seconds or minutes adjustable.

If the external switch has been kept closed or the level has been maintained up to the set value of T1, the countdown is valid, if the external switch is not set to the value of T1 on the break, then stop waiting to start the countdown. For example: you set the T1 for 5 seconds, T2 for 2 seconds, then the external switch pressed for 5 seconds, the relay will pull up for about 2 seconds and then disconnect, otherwise the relay does not pull. If the T1 is set to 5 seconds, T2 is 0, then the external switch is pressed for about 5 seconds, the relay is switched on, the external switch is pressed again for about 5 seconds, and the relay is released.

 

Switch timing trigger demo video:

http://www.tudou.com/programs/view/y6PJVrgwhcg/

P-6: digital tube automatic shutdown settings

P-6 mode is used to set the digital tube automatic closing time (0 ~ 9 minutes, the 0 has been bright), in order to reduce the power consumption of the controller, digital control off the minimum standby current of 6mA/12V. The mode can be operated normally in the closed state of the digital tube, only show off, and the relay action is not affected.

 

Working power interface using bolt type 5.08mm terminal, as shown below:

 

The connection area of the relay is marked with safety warning, and is electrically isolated from the slot to be processed, and the high current lead is added to the solder

The battery can be used for power supply (3-4 section of the dry battery, the battery box needs to be allocatedhttp://item.taobao.com/item.htm?spm=686.1000925.1000774.55.6O7opf&id=17667911115)

 

Specification

Type : Air Conditioner Parts

+