CONTEC CMS6800 Pantient Monitor 8‘’ TFT Color LCD, Standard Parameters ECG, RESP, SpO2, PR, NIBP and TEMP

USD 379.05USD 399.00

CONTEC CMS6800 Pantient Monitor 8‘’ TFT Color LCD, Standard Parameters ECG, RESP, SpO2, PR, NIBP and TEMP

Description

Introduction

The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopts 8'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional external 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.

This device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.

Functions

Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP

1)ECG Heart rate(HR)

ECG waveform

Arrhythmia and ST-segment analysis

2)RESP Respiration rate(RR)

Respiration waveform

3)SpO2 Oxygen saturation(SpO2)

Plethysmogram(PLETH) waveform

Pulse rate(PR)

Bar graph

4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)

5)TEMP T1, T2, TD

It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.

Features

1)8'' TFT color LCD, multi-language interface (Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).

2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.

3)All-round monitor for adult, pediatric and neonate.

4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.

5)Waveform, parameter color and location can be set optionally.

6)Finish all operations by keys and knobs.

7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display

8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.

9)Heart rate variability (HRV) analysis function

10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.

11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.

12)Drug concentration calculation and titration table functions.

13)One-touch printing of trend graph

14)Connect to Central Monitoring System by Wi-Fi or wired mode.

15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.

16)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).

Performance

ECG

Lead mode: 3-lead or 5-lead

Lead selection: I, II, III, aVR, aVL, aVF, V

Waveform: 5-lead, 2-channel

3-lead, 1-channel

Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV

Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s

HR:

Measurement and alarm range: 15~350 bpm

Accuracy: ±1 % or ±1 bpm, whichever is greater

Alarm accuracy: ± 2 bpm

Resolution: 1 bpm

ST-segment monitoring:

Measurement and alarm range: -2 mV ~ +2 mV

Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater

Other range: unspecified

Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Pacemaker: yes

RESP

Method: R-F(RA-LL) Impedance

Respiration rate:

Measurement and alarm range: 0~150 rpm

Resolution: 1 rpm

Measurement accuracy: ±2 rpm

Alarm accuracy: ±3 rpm

Apnea alarm: 10~40s

Scan speed: 12.5 mm/s, 25 mm/s

NIBP

Method: Oscillometry

Mode: Manual/AUTO/STAT

Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes

Measurement period in STAT mode: 5 minutes

Measurement and alarm range: 10 ~ 270 mmHg

Resolution: 1 mmHg

Cuff pressure accuracy: ±3 mmHg

Measurement accuracy:

Maximal mean deviation: ±5 mmHg

Maximal standard deviation: 8 mmHg

Over-pressure protection:

Adult mode: 297±3 mmHg

Pediatric mode: 240±3 mmHg

Neonatal mode: 147±3 mmHg

SpO2

Measurement and alarm range: 0 ~ 100%

Resolution: 1%

Measurement accuracy: 70%~100%: ±2%;

0%~69%: unspecified

PR

Measurement and alarm range: 30 ~ 250 bpm

Measurement accuracy: ±2 bpm or ±2%, whichever is greater

TEMP

Measurement and alarm range: 0 ~ 50℃

Resolution: 0.1℃

Accuracy: ±0.1℃

Power supply: 100-240V~, 50/60Hz

Safety classification: Class I, type CF defibrillation-proof applied part

EtCO2

Method: Sidestream or Mainstream

Measurement range for CO2: 0~150 mmHg

Resolution for CO2:

0.1 mmHg: 0~69 mmHg

0.25 mmHg: 70~150 mmHg

Accuracy for CO2:

0~40 mmHg: ±2 mmHg

41~70 mmHg: ±5%

71~100 mmHg: ±8%

101~150 mmHg: ±10%

AwRR range: 2~150 rpm

AwRR accuracy: ±1 rpm

Apnea alarm: yes

IBP

Channel: dual-channel

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measurement and alarm range: -10~300 mmHg

Resolution: 1 mmHg

Accuracy: ±2% or 1mmHg, whichever is greater

Power supply: 100-240V~, 50/60Hz

Safety classification: Class I, type CF defibrillation-proof applied part

Accessories

1)SpO2 probe extension cable

2)Adult fingertip SpO2 probe

3)Adult NIBP cuff

4)NIBP extension tube

5)ECG lead cable

6)ECG electrode

7)Temperature probe

8)Power cord

9)User Manual

Physical characteristic

Dimension: 227mm(L)x153mm(W)x247mm(H)

Weight: <2.4 kg(excluding accessories)

Specification

Origin : China

Brand Name : CONTECMED

Certification : CE

+