+

CONTEC CMS8000 Multi-Parameter Patient Monitor ICU SPO2 Heart Rate Monitor RESP TEMP ECG PR

USD 566.19USD 699.00

CONTEC CMS8000 Multi-Parameter Patient Monitor ICU SPO2 Heart Rate Monitor RESP TEMP ECG PR

Description

Vital Signs ICU 6-PARA Patient Monitor CMS8000

ECG NIBP SPO2 RESP TEMP PR

Introduction

CMS8000 12.1'' Multi-Parameter Patient Monitor,The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopts 12.1'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.

Features

1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.3)All-round monitor for adult, pediatric and neonate.4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.5)Finish all operations by keys and knobs.6)Maximum 8-channel waveform synchronous display.7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.9)Heart rate variability (HRV) analysis function10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.12)Drug concentration calculation and titration table functions.13)One-touch printing of trend graph14)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.16)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).

Functions

Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP1)ECG Heart rate(HR)ECG waveform Arrhythmia and ST-segment analysis2)RESP Respiration rate(RR)Respiration waveform3)SpO2 Oxygen saturation(SpO2)Plethysmogram(PLETH) waveformPulse rate(PR)Bar graph4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)5)TEMP T1, T2, TD6)IBP(optional) CH1:SYS,DIA,MAPCH2:SYS,DIA,MAPIBP waveform7)CO2(optional) EtCO2InsCO2:Inspired Minimum CO2AwRR:Air Way RespirationIt has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.

Performance

▲ECGLead mode: 3-lead or 5-leadLead selection: I, II, III, aVR, aVL, aVF, VWaveform: 5-lead, dual-channel3-lead, single-channelGain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mVScan speed: 12.5mm/s, 25 mm/s, 50 mm/sHR: Measurement and alarm range: 15~350 bpmAccuracy: ±1 % or ±1 bpm, whichever is greaterAlarm accuracy: ± 2 bpmResolution: 1 bpmST-segment monitoring:Measurement and alarm range: -2.0 mV ~ +2.0 mVAccuracy: -0.8 mV~+0.8 mV  ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCPacemaker: yes▲RESPMethod: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpmResolution: 1 rpmMeasurement accuracy: ±2 rpmAlarm accuracy: ±3 rpmApnea alarm: 10~40sScan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s▲NIBPMethod: OscillometryMode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutesMeasurement period in STAT mode: 5 minutesMeasurement and alarm range: 10 ~ 270 mmHgResolution: 1 mmHgCuff pressure accuracy: ±3 mmHgMeasurement accuracy:Maximal mean deviation: ±5 mmHgMaximal standard deviation: 8 mmHgOver-pressure protection:Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg▲SpO2Measurement and alarm range: 0 ~ 100%Resolution: 1%Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified ▲PRMeasurement and alarm range: 30 ~ 250 bpmMeasurement accuracy: ±2 bpm or ±2%, whichever is greater▲TEMPChannel: dual-channelMeasurement and alarm range: 0 ~ 50℃Resolution: 0.1 ℃Accuracy: ±0.1 ℃

▲EtCO2(OPTIONAL)Method: Sidestream or Mainstream Measuring Range: 0~150mmHgResolution:0~69 mmHg, 0.1 mmHg70~150 mmHg, 0.25 mmHgAccuracy:0~40 mm Hg ±2 mm Hg41~70 mm Hg ±5%71~100 mm Hg ±8%101~150 mm Hg ±10%AwRR Range: 2~150 rpmAwRR Accuracy: ±1BPMApnea Alarm: Yes▲IBP  (OPTIONAL)Channel: dual-channelLabel: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and Alarm Range: -10~300 mmHgResolution 1 mmHgAccuracy: ±2% or 1mmHg, whichever is greater▲Power supply: 100-240V~, 50/60Hz▲Safety classification: Class I, type CF defibrillation-proof applied partPhysical characteristic:Dimension: 314 mm(L) × 145 mm(W) × 264 mm(H)Weight: 3.9 Kg

Package included:

1X CMS8000 Patient Monitor1X Adult fingertip SpO2 probe (5-pin)1X Adult NIBP cuff1X NIBP extension tube1X ECG lead cable1X ECG electrode1X Temperature probe1X Power cord1X User Manual

Specification

Origin : CN

Brand Name : Contec

Certification : CE

Model Number : CMS8000

+