Honeywell humidity/moisture sensor HIH-4000 series

Features

Thermoset plastic housing

Relative to the RH% (relative humidity)

Value of linear voltage output

Laser adjustment interchangeability

Low power design

High-precision

Fast response time

Stable, little drift

Chemical resistance

Typical applications

Refrigeration equipment

Heating, ventilation and air conditioning equipment

Medical equipment

Drying equipment

Measuring equipment

Battery-powered system

Original equipment manufacturer (OEM)

Assembly parts

HIH-4000 series measuring humidity sensor is designed for mass production of an original equipment manufacturer (OEM)

Designed for users. using linear voltage output of the sensor can be entered directly into the controller or other

Devices. need only take the 200 μA current HIH-4000 series measuring humidity sensor can be ideally

For low lead, battery-powered system. good interchangeability of the sensor reduces or eliminates the OEM

Production verification costs. can supply a single sensor calibration data.

HIH-4000 series measuring humidity sensor as a low cost, but a single dip soldering set

(SIP) provides the meter measuring the quality of relative humidity (RH) sensor performance. RH sensor can be used in two

Lead spacing between the assigned amount, it is a thermoset polymer capacitance sensor chip

Signal processing functions. the multilayer structure of the sensing element of adverse environmental factors, such as humidity,

Dust, dirt, oils and common chemicals in the environment with the best resistance.

Honeywell

Table 1: performance specifications

The 5.0 VDC supply voltage and at 25 ° c unless otherwise specified

%RH test system performance specifications include measurement error (± 0.5% typical)

Parameter min Typ Max unit

Interchangeability (best fit straight line)

0 to 60%RH-5 5%RH

60% to 100%-8 8%RH

Interchangeability (CONIC) ± 3.5%RH

* Precision (best fit straight line) ± 3.5%RH

** Accuracy voltage output (second-order curve) ± 2.5%RH

Lag 3%RH

Repeat accuracy ± 0.5%RH

Setting time 70 mS

Response time l/e in the slow-flowing air in 15 Sec

Stability (under the condition of 50%RH in 1 year) ± 1.2%RH

Stability (under 50%RH)%RH

Power supply requirements TBD

4 5.8 of the supply voltage VDC

Supply current: 500 μA

Voltage output (first match) v output =V power supply (0.0062 (sensor RH) +0.16)

Voltage output (second-order curve fitting) v output = 0.00003 (sensor RH) 2 + 0.0281 (sensor RH) +

0.820, the typical data at 25 ° c

V output with temperature compensation = (0.0305+0.000044T-0.0000011T2) (sensor RH)

+ (0.9237-0.0041T+0.000040T2)

T = temperature in ° c

-40 as shown in Figure 1 to 85 ° c operating temperature

-40 185 °F

Operating humidity 0 as shown in Figure 1-100%RH

-40 to 125 ° c storage temperature

-40 257 °F

Storage humidity is shown in Figure 2%RH

* Only-004 and HIH-400-003 models.

** Only for HIH-400-003 and-004 model (information cannot be supplied, please contact your Honeywell sales rep).

Specifications include areas outside the scope of the work recommended by the test data.

Specifications for recommended working areas, only.

Notes:

1. the sensor in an environment not exposed to condensation.

2. exposed to liquid water will cause the sensor indicated as 0%RH.

3. the sensors are of the light sensitive equipment. for best performance, should shield the sensor, avoiding the glare.

4. in an environment exposed to >90%RH reversible drift can cause 3%RH.

5. sensor of electrostatic sensor connections should be protected, up to 15kV.

6. the sensor's output and supply voltage is proportional to.

Model HIH-4000-001

Channel 92

Contacts 030996M

MRP 337313

Values calculated at 5V

VOUT (output), when 0% RH

VOUT (output), when%75.3 RH

0.958 V

3.268 V

2% RH linear output

Accuracy at 25 ° c

Zero offset

The slope of

RH

0.958 V

30.680 mV%RH

(V-output zero offset)/slope

(V output-0.958)/0.0307

0-100%RH proportion of responses

V-v power supply output (0.1915-0.8130)

Figure 3: typical best fit line

Figure 4: typical second-order curve fitting

Relative humidity

Voltage output

Temperature ° c

Relative humidity

Voltage output

     

Specification

Material : Mixture

Output model categories : Analog sensors

Type : DC/AC Inverters

Sensor category : Liquid level sensor

Working principle : Humidity sensor

+