Deputy United States Honeywell HONEYWELL humidity -s HIH-4000-003 imported thermal
Honeywell humidity/moisture sensor HIH-4000 series
Features
Thermoset plastic housing
Relative to the RH% (relative humidity)
Value of linear voltage output
Laser adjustment interchangeability
Low power design
High-precision
Fast response time
Stable, little drift
Chemical resistance
Typical applications
Refrigeration equipment
Heating, ventilation and air conditioning equipment
Medical equipment
Drying equipment
Measuring equipment
Battery-powered system
Original equipment manufacturer (OEM)
Assembly parts
HIH-4000 series measuring humidity sensor is designed for mass production of an original equipment manufacturer (OEM)
Designed for users. using linear voltage output of the sensor can be entered directly into the controller or other
Devices. need only take the 200 μA current HIH-4000 series measuring humidity sensor can be ideally
For low lead, battery-powered system. good interchangeability of the sensor reduces or eliminates the OEM
Production verification costs. can supply a single sensor calibration data.
HIH-4000 series measuring humidity sensor as a low cost, but a single dip soldering set
(SIP) provides the meter measuring the quality of relative humidity (RH) sensor performance. RH sensor can be used in two
Lead spacing between the assigned amount, it is a thermoset polymer capacitance sensor chip
Signal processing functions. the multilayer structure of the sensing element of adverse environmental factors, such as humidity,
Dust, dirt, oils and common chemicals in the environment with the best resistance.
Honeywell
Table 1: performance specifications
The 5.0 VDC supply voltage and at 25 ° c unless otherwise specified
%RH test system performance specifications include measurement error (± 0.5% typical)
Parameter min Typ Max unit
Interchangeability (best fit straight line)
0 to 60%RH-5 5%RH
60% to 100%-8 8%RH
Interchangeability (CONIC) ± 3.5%RH
* Precision (best fit straight line) ± 3.5%RH
** Accuracy voltage output (second-order curve) ± 2.5%RH
Lag 3%RH
Repeat accuracy ± 0.5%RH
Setting time 70 mS
Response time l/e in the slow-flowing air in 15 Sec
Stability (under the condition of 50%RH in 1 year) ± 1.2%RH
Stability (under 50%RH)%RH
Power supply requirements TBD
4 5.8 of the supply voltage VDC
Supply current: 500 μA
Voltage output (first match) v output =V power supply (0.0062 (sensor RH) +0.16)
Voltage output (second-order curve fitting) v output = 0.00003 (sensor RH) 2 + 0.0281 (sensor RH) +
0.820, the typical data at 25 ° c
V output with temperature compensation = (0.0305+0.000044T-0.0000011T2) (sensor RH)
+ (0.9237-0.0041T+0.000040T2)
T = temperature in ° c
-40 as shown in Figure 1 to 85 ° c operating temperature
-40 185 °F
Operating humidity 0 as shown in Figure 1-100%RH
-40 to 125 ° c storage temperature
-40 257 °F
Storage humidity is shown in Figure 2%RH
* Only-004 and HIH-400-003 models.
** Only for HIH-400-003 and-004 model (information cannot be supplied, please contact your Honeywell sales rep).
Specifications include areas outside the scope of the work recommended by the test data.
Specifications for recommended working areas, only.
Notes:
1. the sensor in an environment not exposed to condensation.
2. exposed to liquid water will cause the sensor indicated as 0%RH.
3. the sensors are of the light sensitive equipment. for best performance, should shield the sensor, avoiding the glare.
4. in an environment exposed to >90%RH reversible drift can cause 3%RH.
5. sensor of electrostatic sensor connections should be protected, up to 15kV.
6. the sensor's output and supply voltage is proportional to.
Model HIH-4000-001
Channel 92
Contacts 030996M
MRP 337313
Values calculated at 5V
VOUT (output), when 0% RH
VOUT (output), when%75.3 RH
0.958 V
3.268 V
2% RH linear output
Accuracy at 25 ° c
Zero offset
The slope of
RH
0.958 V
30.680 mV%RH
(V-output zero offset)/slope
(V output-0.958)/0.0307
0-100%RH proportion of responses
V-v power supply output (0.1915-0.8130)
Figure 3: typical best fit line
Figure 4: typical second-order curve fitting
Relative humidity
Voltage output
Temperature ° c
Relative humidity
Voltage output
Material : Mixture
Output model categories : Analog sensors
Type : DC/AC Inverters
Sensor category : Liquid level sensor
Working principle : Humidity sensor