+

Digital Dual Thermometer Temperature Controller Thermostat Incubator Control DC24v

USD 8.59

Digital Dual Thermometer Temperature Controller Thermostat Incubator Control DC24v

Description

start

Compensated crystal components FOR Yaesu FT-817/85...US $10.78
3s 4s 12V lithium battery capacity Tester display ...US $2.13
3S 20A Li-ion Lithium 18650 Battery BMS Protection...US $3.34
13pcs Full ER11 Spring Collet Set For CNC Workhold...US $22.87
Jacobs ladder high-tension arc Student experiment ...US $23.78
dc 24v K-type intelligent digital PID thermostat t...US $7.43
Kit Nodemcu 5w 4~12v Usb Fan Stepless Governor Adj...US $3.71
Single regulated power supply module Single DC 5V ...US $1.56
Finished Precision USB Charging Detector Type-C di...US $43.70
4 USB DC 7V~14V 12V9V To 5V 5A Mini Cell Phone Cha...US $7.52

end

 

 

DC 24V Digital LED Dual Thermometer Temperature Controller Thermostat Incubator Control Microcomputer Dual Probe
 
 
  
 Description:
  • Features: 

     

     This is a dual display and dual control temperature controller,it can both control refrigeration or heating of two products, setting method is same of left and right.

    *Technical parameters.

    Temperature control range:-50℃~110℃

    Temperature measurement error:±0.5℃

    Sensor model:ntc(10K/3435)

    Control precision:DC24V

    Working current:MAX200Ma

    Relay contact current:AC5A/220V

     

    Date preserve:available.

     

    Working temperature:0℃~50℃

    Storage temperature:-10℃~60℃

    Meter length:90mm(L)*60mm(W)*26.5mm(H)

    Hole size:70mm(L)*50mm(H)l

    Distribution probe length is 1m,Probe size: Φ4mm*20mm

    *Menu code description

     

    Menu code

    Specify

    Explanation

    Unit

    HC

    Refrigeration/heating

    Thermostat working mode set

    H=Heating C=Cooling

    D

    Return difference

    Temperature difference  between    startup &shutdown

    LS

    Ultralow temperature

    AL-L

    HS

    Ultra-temperature

    AL-H

    CA

    Temperature correction

     

    PT

    Delay start

    Minimum downtime

    MInute

    1. Set the left control temperature

    Press the “SET”Key board and left screen flashes.Press “UP” and “ Down “key board to adjust temperature range,press right “UP” or “Down”key board (Any one) to preserve then exit.

    1. Set the right control temperature

    Press twice “SET”board and right screen flashes, Press”UP” and “Down”Key board to adjust temperature,press right “UP” and “Down”board(any one) to preserve then exit.

    Start and stop timing

    Under the state of standby electric to press the “SET” once, start timing output ,screen alternately.

    Press the “SET” Key board three seconds enter into the setting of control parameters.

    Press ▲or ▼ key board choose adjust menu . then press SET key board once again to enter into the related state of control parameter setting, press ▲or ▼ key board to adjust parameters which requires modify. Press “SET” key board to exit after adjusted ,or exited from delayed 6 seconds system.

    Cooling .heating mode setting

    Press ”SET” key board less than 3 seconds ,enter into menu display, the code “HC” is displaying on screen, press “set” key board displayed working mode.Press”▲” or “▼”to adjust parameters .”C” means cooling mode ,”H” means heating mode.

    ◆Return difference function;

    Maximum temperature was restricted with return difference between start up and close down.

    Return difference setting.

    Press ”SET” key board less than 3 seconds, enter into the menu display, press “▲” or “▼” key board to adjust code until screen displayed “D” code, press “SET” keyboard to displayed value of return difference. Press the “▲” and “▼” keyboard again to adjust parameters.

    Temperature correction function

    When there has deviations between measurement temperature and standard temperature. Machine measurement value and standard temperature can adjust to same under function of temperature correction. Temperature after correction=Temperature before correction +value of correction (Value of correction can be positive number ,negative number and zero)

    Temperature correction setting.

    Press ”SET” keyboard less than 3 seconds, enter into menu display, press “▲” or “▼” keyboard to adjust code until screen displayed “CA”, press ”SET” keyboard display temperature correction value, Press the “▲” and “▼” keyboard again to adjust parameters.

    Delay protection function:

    Press ”SET” Keyboard less than 3 minutes .enter into the menu display . press “▲” or “▼” keyboard to adjust code until screen displayed “PT”, Press “SET” keyboard displayed delay protection setting,Press the “▲” and “▼”keyboard again to adjust parameters.

    Ultra-temperature alarm function

    If measurement temperature ≥control temperature +AH alarm relay actuated , temperature controller alarming ,display screen alternated displaying “H” and present temperature. Then press anyone keyboards to stop alarming and turn off alarm relay output

     

    Ultra-temperature alarm setting

    Press “    SET” keyboard less than 3 seconds , enter into menu display,press “▲” or “▼” keyboard to adjust code until screen displayed “HS” .Press ‘SET” keyboard displayed the set value of ultra-temperature, press  “▲” or “▼”keyboard again to adjust parameters , Set up “HS as “0”,you can turn off the alarm function.

    Ultralow temperature alarm function

    measurement temperature < control temperature-LS alarm relay actuated ,

    temperature controller alerting . Display screen alternated displaying “L ”and present temperature ,press anyone keyboard and turn off relay output.

    Ultralow temperature alarm setting

    Press “SET” keyboard less than 3 seconds ,enter into menu display,press “▲” or “▼” keyboard to adjust code until screen displayed “LS”, press ”SET” keyboard displayed the set value of ultralow temperature, press  “▲” or “▼” keyboard again to adjust parameters ,Set up “LS” as “0”,you can turn off the alarm function.

    Status of the Indicator light introduction.

    Green means working indicator light , green light long bright means state of cooling or heating. Red light flicking means delay to start up and it with function of setting.Red light long bright means in state of setting.

    Press “SET” 3 seconds enter into system high ranking menu setting .During the progress of setting ,press “▲” or “▼” keyboard to choose menu which need to adjust.Then press “SET” keyboard once again enter into state of related controller parameters setting,,press “▲” or “▼” keyboard to adjust the controller parameters which need to modify,Exited by press ”SET” keyboard after adjustment.Temperature controller restart automatically.

     

    Disturbance Display.

    1. When sensor disconnected, screen displaying “LLL”
    2. When sensor detectedtemperaturebelow measurement range,screen displaying EEE”
    3. When sensor detected temperature higher than measurement range ,screen displaying “HHH”

    7.Caution

    ◆ Connect to the correct working voltage ,machine is regular working within the range of ±10%standard input voltage

    ◆Connect to the power load less than maximum control power of temperature controller. If exceed please using with AC contactor.

    ◆Connect to the correct power source ,load, sensor , temperature controller will damaged after connected to wrong wire.

     

    • Please don’t make the wire of sensor and power wires parallel connection.

     

    Package Contents 100% Brand New 1 x Digital LED Dual Thermometer Temperature Controller  

 
Shipping :
    •  

      Country

      Delivery Time

      Working Days (not including holiday)
      5-7
      8-10
      11-14
      15-19
      20-22
      >25
      Working Days + Saturday + Sunday
      5-9
      10-14
      15-20
      21-25
      26-30
      >35
      United States
      Rate (item arrived)    
      9%
      50%
      21%
      13%
      7%
      Refund or Resend
      United Kingdom
      Rate (item arrived)
      10%
      62%
      20%
      3.5%
      4.5%
      Refund or Resend
      Australia
      Rate (item arrived)
      23%
      50%
      13%
      8%
      6%
      Refund or Resend
      France
      Rate (item arrived)
      1.5%
      20.5%
      45%
      23%
      10%
      Refund or Resend
      Germany
      Rate (item arrived)
      5.5%
      25%
      35%
      19%
      15.5%
      Refund or Resend

      Canada

      Rate (item arrived)

      0.0%

      44%

      35%

      18%

      3%

      Refund or Resend

      Spain
      Rate (item arrived)
      1.5%
      25%
      50%
      14%
      9.5%
      Refund or Resend
 
Payment : 
  •  

 
Feedback
  • We maintain high standards of excellence   and strive for 100% customer satisfaction!  Feedback is very important to us. We request that you contact us immediately BEFORE you give us neutral  or negative  feedback, so that we can satisfactorily address your concerns. We greatly appreciate your POSITIVE feedback. Please do NOT leave negative feedback without asking for help.We will try our best to solve any problem. If you have any questions, please feel free to contact us by ebay message. We will reply you within 48 Hours.  
 
Refund&Reship:
  • If you are dissatisfied with our item or service, then please follow the good eBay practice to contact us by ebay message before leaving any feedback. We are committed to resolve all issues in a friendly and satisfactory manner. We always reply to ebay messages within 1-2 business days. If you do not get a response from us, then please check your ebay message. we only reply ebay message, no send email. Original and return shipping fee will not be refunded or reimbursed under all circumstances. You must agree and acknowledge this term if you bid for this item. Therefore, please do not complain about having to ship back at your own expense. Contact US:: If have any question, Please contact us by ebay message(no e-mail). Reply within 24hours. We care about our valued buyers, if you have any questions, our Customer Service staffs will be very glad to help you. We try our best to reply to your emails as soon as possible, however, due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately.

 

Specification

Model Number : OEM

Type : Voltage Regulator

Current : A

Dissipation Power : w

Supply Voltage : v

Operating Temperature : stamdard

Voltage : V

is_customized : Yes

Brand Name : NoEnName_Null

Condition : New

Capacity : AH

Power : W

Usage : Laptop

AD2S82AHPZ AD2S82AHP AD2S82 R/D
USD 66.40USD 69.89
+