Timer Relay DC 5V 12V 24V Digital Time Delay Relay Switch Controller Programmable Module Trigger Cycle 0.1s-99min 16-Work Mode

USD 4.93USD 6.16

Timer Relay DC 5V 12V 24V Digital Time Delay Relay Switch Controller Programmable Module Trigger Cycle 0.1s-99min 16-Work Mode

Description

Description:

  • WIDE VOLTAGE: Working voltage is suitable for most equipment. Support micro USB 5V power supply. It can be used to control the equipment within DC 30V 5A or within AC 220V 5A.

  • TRIGGER: Support a variety of trigger signal sources, such as high-level trigger, switch trigger, serial communication trigger, PNP sensor. In addition, there are 16 working modes, including 4 modes without triggering and 12 modes requiring triggering.

  • WIDE TIMING RANGE: Minimum 0.1 seconds, maximum 999 minutes, continuously adjustable. It can be able to set OP, CL, LOP, CLL, CLH parameters, and they are independent of each other and saved separately.

  • FUNCTION: EMERGENCY STOP--Built-in one-key emergency stop function, with reverse connection protection and optocoupler isolation. All parameters are automatically saved after power failure.Support UART communication function;Support parameter memory function;Support forced stop function

  • SLEEP MODE: After power on, if there is no operation for 3 minutes, the display will automatically turn off, press any key to wake up.

Specification

  • Working Voltage: DC 5.0V~30V

  • Trigger Type: Button/PNP/NPN/High/Low Level Signal

  • High Trigger Signal: DC 3.0V~24V

  • Output Type: Relay Switch Output(No voltage output)

  • Load(Max): DC 30V 10A or AC 250V 10A

  • Work Current: 50mA

  • Quiescent Current: 20mA

  • Working Temperature range: -40℃~85℃

  • Working Humidity Range: 5%-95%RH

  • Module Size: 79*43*26mm

Parameter Description
  • OP: Delay time for turn On;

  • CL: Delay time for turn OFF;

  • LOP: Number of cycles.Range is 1-999tims. ’----’ means unlimited loop.

  • CLL: Minimum value of random delay time range. The setting range is 0.0~99.9second. This CLL parameter is used for P15 work mode.

  • CLH: Maximum value of random delay time range.The setting range is 0.0~99.9second. This CLH parameter is used for P15 work mode. CLH value is greater than CLL value.

Use Steps

  1. Determine the working mode of the module;

  2. According to the working mode, on the main interface (when the module is powered on, it will flash the current working mode (default P01 mode), and then enter the main interface) "long press the SET button for 2 seconds and release it" to enter the mode selection interface , short pressing the UP and DOWN buttons to sett the mode(P00-P15) ;

  3. After setting the mode(such as P03), short press the SET button to set the parameters, then the parameters will flash (OP on time, CL off time, LOP cycle times ( "---" Represents infinite loops)), adjust the parameter value through UP and DOWN. Support long press and short press;

  4. After setting the parameter value, short press the STOP key to set the decimal point position and select the timing range (0.1 seconds ~ 999 minutes); short press the SET key to set the next parameter, the process is the same as above;

  5. P15 mode: After selecting the mode, short press the SET key to set the parameters, then the parameters will flash (CLL disconnection time lower limit, CLH disconnection time upper limit), adjust the parameters through UP and DOWN value. Support long press and short press , timing range (0.1 seconds ~ 99.9 seconds); short press the SET key to set the next parameter, the process is the same as above ;

  6. 6.After setting the parameters of the selected mode, long press the SET button for 2 seconds and then release, the currently set mode will flash, and then return to the main interface, the parameter setting is successful!

Specification

Power supply : Support micro USB 5V

Model Number : Timer Relay

Trigger Type : Button/PNP/NPN/High/Low Level Signal

Wide voltage : Suit for most equipment

Origin : Mainland China

Brand Name : IS

Working modes : 16 Kinds

Supply Voltage : DC 5-30V

Condition : New

Work Current : 50mA

High Trigger Signal : DC 3.0V~24V

Quiescent Current : 20mA

Load(Max) : DC 30V 10A or AC 250V 10A

WIDE TIMING RANGE : 0.1s - 999 minutes

Type : Voltage Regulator

Module Size : 79*43*26mm

Output Type : Relay Switch Output(No voltage output)

Function : Emergency stop function

Sleep mode : auto turn off

Feature : 2200W 10A Relay Driver

Feature1 : Optocoupler isolation protection

Feature2 : Support UART communication function

Feature3 : Support parameter memory function

Feature4 : Support forced stop function

+