Timer Relay DC 5V 12V 24V Digital Time Delay Relay Switch Controller Programmable Module Trigger Cycle 0.1s-99min 16-Work Mode
Description:
WIDE VOLTAGE: Working voltage is suitable for most equipment. Support micro USB 5V power supply. It can be used to control the equipment within DC 30V 5A or within AC 220V 5A.
TRIGGER: Support a variety of trigger signal sources, such as high-level trigger, switch trigger, serial communication trigger, PNP sensor. In addition, there are 16 working modes, including 4 modes without triggering and 12 modes requiring triggering.
WIDE TIMING RANGE: Minimum 0.1 seconds, maximum 999 minutes, continuously adjustable. It can be able to set OP, CL, LOP, CLL, CLH parameters, and they are independent of each other and saved separately.
FUNCTION: EMERGENCY STOP--Built-in one-key emergency stop function, with reverse connection protection and optocoupler isolation. All parameters are automatically saved after power failure.Support UART communication function;Support parameter memory function;Support forced stop function
SLEEP MODE: After power on, if there is no operation for 3 minutes, the display will automatically turn off, press any key to wake up.
Working Voltage: DC 5.0V~30V
Trigger Type: Button/PNP/NPN/High/Low Level Signal
High Trigger Signal: DC 3.0V~24V
Output Type: Relay Switch Output(No voltage output)
Load(Max): DC 30V 10A or AC 250V 10A
Work Current: 50mA
Quiescent Current: 20mA
Working Temperature range: -40℃~85℃
Working Humidity Range: 5%-95%RH
Module Size: 79*43*26mm
OP: Delay time for turn On;
CL: Delay time for turn OFF;
LOP: Number of cycles.Range is 1-999tims. ’----’ means unlimited loop.
CLL: Minimum value of random delay time range. The setting range is 0.0~99.9second. This CLL parameter is used for P15 work mode.
CLH: Maximum value of random delay time range.The setting range is 0.0~99.9second. This CLH parameter is used for P15 work mode. CLH value is greater than CLL value.
Determine the working mode of the module;
According to the working mode, on the main interface (when the module is powered on, it will flash the current working mode (default P01 mode), and then enter the main interface) "long press the SET button for 2 seconds and release it" to enter the mode selection interface , short pressing the UP and DOWN buttons to sett the mode(P00-P15) ;
After setting the mode(such as P03), short press the SET button to set the parameters, then the parameters will flash (OP on time, CL off time, LOP cycle times ( "---" Represents infinite loops)), adjust the parameter value through UP and DOWN. Support long press and short press;
After setting the parameter value, short press the STOP key to set the decimal point position and select the timing range (0.1 seconds ~ 999 minutes); short press the SET key to set the next parameter, the process is the same as above;
P15 mode: After selecting the mode, short press the SET key to set the parameters, then the parameters will flash (CLL disconnection time lower limit, CLH disconnection time upper limit), adjust the parameters through UP and DOWN value. Support long press and short press , timing range (0.1 seconds ~ 99.9 seconds); short press the SET key to set the next parameter, the process is the same as above ;
6.After setting the parameters of the selected mode, long press the SET button for 2 seconds and then release, the currently set mode will flash, and then return to the main interface, the parameter setting is successful!
Power supply : Support micro USB 5V
Model Number : Timer Relay
Trigger Type : Button/PNP/NPN/High/Low Level Signal
Wide voltage : Suit for most equipment
Origin : Mainland China
Brand Name : IS
Working modes : 16 Kinds
Supply Voltage : DC 5-30V
Condition : New
Work Current : 50mA
High Trigger Signal : DC 3.0V~24V
Quiescent Current : 20mA
Load(Max) : DC 30V 10A or AC 250V 10A
WIDE TIMING RANGE : 0.1s - 999 minutes
Type : Voltage Regulator
Module Size : 79*43*26mm
Output Type : Relay Switch Output(No voltage output)
Function : Emergency stop function
Sleep mode : auto turn off
Feature : 2200W 10A Relay Driver
Feature1 : Optocoupler isolation protection
Feature2 : Support UART communication function
Feature3 : Support parameter memory function
Feature4 : Support forced stop function