VFD Inverter 75KW 380V 3 Phase Frequency Inverter Display Speed Control Frequency Converter For Three Phase Induced Fan Motor

USD 1411.87USD 2393.00

VFD Inverter 75KW 380V 3 Phase Frequency Inverter Display Speed Control Frequency Converter For Three Phase Induced Fan Motor

Description

VFD Inverter 75KW 380V 3 Phase Frequency Inverter Display Speed Control Frequency Converter For Three Phase Induced Fan Motor

Type Selection Table

380V/132KW

380V/75KW

380V/93KW

380V/110KW

Model NO.

WK600-1320-G3T

WK600-0750-G3T

WK600-0930-G3T

WK600-1100-G3T

Input voltage

3 phase 380V±10% 50Hz/60Hz

Output voltage

Three phase 0-380V 0-500Hz

Power

132KW/75HP

75KW/100HP

93KW/125HP

110KW/150HP

Rated current

250A

150A

180A

210A

Shape size(mm)

580*370*330

packing size(mm)

620*390*370

Weight

42KG

42KG

42KG

42KG

Type selection instructions:

1. Please read the product instructions carefully, choose the type according to the function and power you need, and avoid the damage caused by wrong wiring.

2. This Frequency converter does not support single-phase motor speed regulation with capacitance.

3. Speed regulation of three-phase AC motors with six or more stages. Please purchase a converter with higher power than the motor.

4. If you don't know how to choose the type, you can also contact us to give you some suggestions.

Supplementary Note:

A. If you need detailed version of product manual, you can contact us to send it to you free of charge.

B. If there is no paper product manual in the packing case, it is because of product changes or upgrades. Please contact us for the latest and accurate electronic product manual.

wiring diagram

Supplementary Note:
 

R, S, T are input terminals of three-phase power supply of frequency converter.

U, V, W are output terminals of frequency converter, and connected three-phase asynchronous motor.

DETAILS OF OUR PRODUCTS

◆ 5-digit tube display      ◆ High quality components    ◆ DC Heat Dissipating Fan    ◆ Isolated aluminium heat dissipation base
 

OUR PRODUCT TECHNOLOGY

Item

Description

Standard functions

Maximum frequency

Vector control: 0-500HzV/F control: 0-500Hz

Carrier frequency

1-16 kHzThe carrier frequency is automatically adjusted based on the load features.

Input frequency resolution

Digital setting: 0.01 HzAnalog setting: Max. frequency x 0.025%

Control mode

Sensorless vector control (SVC)Frequency (V/F) control

Startup torque

0.25 Hz/150% (SVC)

Speed range

1:200 (SVC)

Speed stability accuracy

±0.5% (SVC)

Torque control accuracy

±5% for 10 Hz above (SVC)

Torque boost

Customized boost 0.1 % to 30.0 %

V/F curve

Straight-line V/F curve; Multi-point V/F curve; Square V/F curve; Complete V/F separation;Half V/F separation

Ramp mode

Straight-line ramp S-curve rampFour separate acceleration/deceleration time settings in the range of 0s to 6500s.

DC injection braking

DC injection braking frequency: 0 Hz to max. frequency DC injection braking active time: 0.0s to 36.0s.Current level of DC injection braking: 0% to 100%.

Jog running

Frequency range of jog running: 0.00 to 50.00 HzAcceleration/Deceleration time of jog running:0.0s to 6500.0s

Onboard multiple preset speeds

The system implements up to 16 speeds by using simple PLC function or by using digital input signals.

Onboard PID

The system implements the proportionalegral-derivative (PID) function in the closed-loop control.

Automatic voltage regulation (AVR)

The system maintains a constant output voltage automatically when the grid voltage changes through the permissible range.

Overvoltage and overcurrent stall control

The system limits the output current and voltage automatically during operation to prevent frequent or excessive trips.

Torque limit and control

The system limits the torque automatically to prevent frequent overcurrent tripping during operation.

Individualized functions

Power dip ride-through

Load feedback energy compensates for any voltage reduction, allowing the drive to continue to operate for a short time during power dips.

Overcurrent fast prevention

The function helps to avoid frequent overcurrent faults.

Virtual I/O

Five groups of virtual digital input/outputs (X /DO) support simple logic control.

Timing control

Time range: 0.0 to 6500.0 minutes

Dual-motor switchover

The drive have two groups of motor parameters and can control up to two motors.

Multiple field buses

The drive supports four field buses:Modbus-RTU; PROFIBUS-DP; CANlink; CANopen

RUN

Command source

Allows different methods of switching between command sources:Operating panel (keypad & display) Terminal I/O controlSerial communication

Main frequency reference setting channel

Supports up to 10 frequency reference setting channels and allows different methods of switching between frequency reference setting channels:Digital settingAnalog voltage reference Analog current reference Pulse reference Communication reference

Auxiliary frequency reference setting channel

Supports up to 10 auxiliary frequency sources, and allows fine tuning of the auxiliary frequency and main & auxiliary calculation.

Input terminals

Standard:Six digital input (X) terminals, one of which supports up to 100 kHz high-speed pulse inputs.Two analog input (AI) terminals, one of which supports only 0 to10 V input, and the other supports 0 to 10 V and 4 to 20 mA current input.

Output terminals

Standard:Single high-speed pulse output terminal (open-collector) for a square-wave signal output in the frequency range 0 to 100 kHzSingle digital output (DO) terminal Single relay output terminalSingle analog output (AM) terminal that supports either a current output in the range 4 to 20 mA or a voltage output in the range 0 to 10 V.

Key locking and function selection

Keys on the control panel can be locked or partially locked electronically to prevent accidental operation.The range of some functions can be limited to a permitted range to prevent incorrect settings.

Protections

Phase loss protection

Input phase loss protectionOutput phase loss protection

Instantaneous overcurrent protection

Stop when 200% of rated output current is exceeded

Overvoltage protection

Stop when the DC bus voltage is above 800 V

Undervoltage protection

Stop when the DC bus voltage is below 350 V

Overheat protection

Protection triggered when the AC Drive bridge gets overheated.

Overload protection

Stop after running at 150% of rated current for 60 seconds

Overcurrent protection

Stop when 2.0 times of rated current of the AC drive is exceeded.

Braking protection

Braking unit overload protectionBraking resistor short-circuit protection

Short-circuit protection

Output phase-to-phase short-circuit protectionOutput phase-to-ground short-circuit protection

Environment

Installation location

Install the AC Drive where it is indoors and protected from direct sunlight, dust, corrosive or combustible gases, oil smoke, vapour, ingress from water or any other liquid, and salt.

Altitude

Below 1000 mIf the altitude exceeds 1000 m, de-rate the drive according to section 1.5 De-rating.Max. 3000 m for LVD directive requirement.

Operation temperature

-10℃ to +50℃If the ambient temperature is not in this range, de-rate the drive according to section 1.5 De-rating.

Storage temperature

-20℃ to +60℃

Humidity

Less than 95% RH non-condensing.

Vibration

Less than 5.9 m/s2 (0.6 g).

Pollution degree

PD2

Overvoltage category

OVC III

BUYING INSTRUCTIONSBUYING INSTRUCTIONSBUYING INSTRUCTIONSBUYING INSTRUCTIONSBUYING INSTRUCTIONSBUYING INSTRUCTIONSBUYING INSTRUCTIONSBUYING INSTRUCTIONS

Please note:We are not responsible for any custom duty or import tax!

Payment

A. Please make payment by Secure payment in advance and so that we can arrange shipment in time.

B. Please write your detailed delivery address, contact information and phone number on payment. It is very important to deliver package successfully. Please make sure your address in Aliexpress is matched with your shipping address before you pay. Specially, for Russian customer, must write the full name (the first name, middle name, last name). Thanks very much.

C. We are not responsible for any custom duty or import tax. Please check with your country customs office to determine what these additional costs will be before bidding/buying.

Delivery

A. All package is standard paper box packing or wooden packing for big order.

B. Please note the delivery date using different Express, so please choose the right delivery according to your need.

C. If you prepare to big order ,please contact us if want delivery by any other method.

D. All packages will shipped with a Tracking Number.

Feedback

Your positive feedback is highly appreciated. We guarantee the quality of our products. Each item will be checked carefully before delivery. Please contact us immediately if there is any reason you feel. We will try our best to satisfy you.

If you are satisfied with our products and service, please kindly leave a positive five star (★★★★★) feedback for us. It is very important for us . Thanks very much in advance.

Contact us

We will reply to your inquiries as immediately as possible. However, please note that we have 12-16 hours time difference with western Europe and 8 hours time difference with U.S.A. Therefore, we promise will try best to reply within 24 hours.

For bulk orders, please contact us for details. We can give you an appropriate discount.

Specification

Output Current : 150A/180A/210A/250A

Output Frequency : 0-500Hz

Output Power : 75KW/93kw/110kw/132kw

is_customized : Yes

Type : DC/AC Inverters

Brand Name : CNWeiKen

Weight : 42KG

Output Type : Triple

Origin : Mainland China

Size : 470*290*220

Relay output : Normally open and normally close

Control Mode : Open loop vector control(SVC) V/F control

10V Output Voltage : Yes

Certification : CE

Model Number : WK600

24V Output Voltage : Yes

Input Voltage : Three-phase 380V

Output Voltage : Three-phase 380V

+