XK-W2001 Digital Microcomputer Thermostat Electronic Thermostat Socket Temperature Control Switch Aquaculture Thermostat Socket

USD 3.42USD 5.51

XK-W2001 Digital Microcomputer Thermostat Electronic Thermostat Socket Temperature Control Switch Aquaculture Thermostat Socket

Description

Product selling point

1: Widely used

2: Exquisite appearance

3: Convenience and simplicity

4: 1M waterproof line probe

5: The setup is simple and easy to understand

Product name: Microcomputer temperature controller

Temperature measurement range: -50~110℃

Temperature control range: -50~110~c

Temperature measurement accuracy: ±0.2℃

Temperature control accuracy: ±0.1℃

Measurement input: NTC10K L=1 meter waterproof probe

Input power: 110V-220V

Output power: 1500W

output type: direct output

Output capacity: max 10A

Appearance size: 120*59*30mm

Code and function introduction

PO set startup temperature

Press the setting button once to enter the internal menu, the default display is P0, press the setting button again, and set the required startup temperature by pressing the up and down buttons.

P1 set stop temperature

Press the setting button once to enter the internal menu, the digital display is P0, switch to P1 by pressing the up and down buttons, press the setting button again, and set the desired stop temperature by pressing the up and down buttons.

P2 set temperature correction

Enter the internal menu in the same way, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by pressing the up and down buttons. In the setting, if the detected temperature value is 0.5°C higher than the actual temperature value, the calibration temperature to be set is -0.5°C. If the detected temperature value is 1°C lower than the actual temperature value, the calibration temperature to be set is 1°C. Detected temperature±corrected temperature=actual temperature.

P3 set delay start

Enter the internal menu in the same way, switch to P3 by pressing the up and down keys, press the setting key again, and set the required delay time (unit is minutes) by pressing the up and down keys. Delay start is generally used for compressor refrigeration. If it is used for refrigerator freezers, this value needs to be set. According to the size of the compressor back pressure, the general setting value is 3-6 minutes. If you are not used to control the compressor or do not need delay time function, skip this item directly

How to set the heating mode

Setting essentials: start temperature < stop temperature (the program automatically determines that the working mode is heating mode)

How to set:

Press the setting key to enter the internal menu, set the start temperature by setting the P0 value, and set the stop temperature by setting the P1 value

Use Cases:

Control the water heater, stop heating when it reaches 50°C, and start heating again when the temperature drops to 40°C. How to set it?

Step 1: Determine the working mode as heating mode, start temperature < stop temperature

Step 2: Press the set key to enter the internal menu, select P0 and press the set key, set the value of P0 to 40°C

Step 3: Press the set key to enter the internal menu, select P1 and press the set key, set the value of P1 to 50°C

Cooling mode setting method

Setting essentials: start temperature > stop temperature (the program automatically determines that the working mode is the cooling mode)

How to set:

Press the setting key to enter the internal menu, set the start temperature by setting the P0 value, and set the stop temperature by setting the P1 value

Use Cases:

Control the radiator of the cabinet, stop the heat dissipation when it reaches 26°C, and start the radiator again when the temperature rises to 30°C. How to set it?

Step 1: Make sure the working mode is cooling mode, start temperature > stop temperature

Step 2: Press the set key to enter the internal menu, select P0 and press the set key, set the value of P0 to 30°C

Step 3: Press the set key to enter the internal menu, select P1 and press the set key, set the value of P1 to 26°C

hint:

When setting the heating mode, if you accidentally reverse the set temperature value, the output indicator will not light up, and the load will not work. After the setting is completed, if the above situation occurs, you can check whether the set temperature value is reversed.

list

1*Temperature Controller

Specification

Supply Voltage : 110V-220V

Model Number : Microcomputer temperature controller

Dissipation Power : 1500W

Operating Temperature : -50~110℃

Origin : Mainland China

Brand Name : Ziqqucu

Package : SOP

Application : Computer

Condition : New

Type : Voltage Regulator

is_customized : Yes

+