XK-W2001 Digital Microcomputer Thermostat Electronic Thermostat Socket Temperature Control Switch Aquaculture Thermostat Socket
Product selling point
1: Widely used
2: Exquisite appearance
3: Convenience and simplicity
4: 1M waterproof line probe
5: The setup is simple and easy to understand
Product name: Microcomputer temperature controller
Temperature measurement range: -50~110℃
Temperature control range: -50~110~c
Temperature measurement accuracy: ±0.2℃
Temperature control accuracy: ±0.1℃
Measurement input: NTC10K L=1 meter waterproof probe
Input power: 110V-220V
Output power: 1500W
output type: direct output
Output capacity: max 10A
Appearance size: 120*59*30mm
Code and function introduction
PO set startup temperature
Press the setting button once to enter the internal menu, the default display is P0, press the setting button again, and set the required startup temperature by pressing the up and down buttons.
P1 set stop temperature
Press the setting button once to enter the internal menu, the digital display is P0, switch to P1 by pressing the up and down buttons, press the setting button again, and set the desired stop temperature by pressing the up and down buttons.
P2 set temperature correction
Enter the internal menu in the same way, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by pressing the up and down buttons. In the setting, if the detected temperature value is 0.5°C higher than the actual temperature value, the calibration temperature to be set is -0.5°C. If the detected temperature value is 1°C lower than the actual temperature value, the calibration temperature to be set is 1°C. Detected temperature±corrected temperature=actual temperature.
P3 set delay start
Enter the internal menu in the same way, switch to P3 by pressing the up and down keys, press the setting key again, and set the required delay time (unit is minutes) by pressing the up and down keys. Delay start is generally used for compressor refrigeration. If it is used for refrigerator freezers, this value needs to be set. According to the size of the compressor back pressure, the general setting value is 3-6 minutes. If you are not used to control the compressor or do not need delay time function, skip this item directly
How to set the heating mode
Setting essentials: start temperature < stop temperature (the program automatically determines that the working mode is heating mode)
How to set:
Press the setting key to enter the internal menu, set the start temperature by setting the P0 value, and set the stop temperature by setting the P1 value
Use Cases:
Control the water heater, stop heating when it reaches 50°C, and start heating again when the temperature drops to 40°C. How to set it?
Step 1: Determine the working mode as heating mode, start temperature < stop temperature
Step 2: Press the set key to enter the internal menu, select P0 and press the set key, set the value of P0 to 40°C
Step 3: Press the set key to enter the internal menu, select P1 and press the set key, set the value of P1 to 50°C
Cooling mode setting method
Setting essentials: start temperature > stop temperature (the program automatically determines that the working mode is the cooling mode)
How to set:
Press the setting key to enter the internal menu, set the start temperature by setting the P0 value, and set the stop temperature by setting the P1 value
Use Cases:
Control the radiator of the cabinet, stop the heat dissipation when it reaches 26°C, and start the radiator again when the temperature rises to 30°C. How to set it?
Step 1: Make sure the working mode is cooling mode, start temperature > stop temperature
Step 2: Press the set key to enter the internal menu, select P0 and press the set key, set the value of P0 to 30°C
Step 3: Press the set key to enter the internal menu, select P1 and press the set key, set the value of P1 to 26°C
hint:
When setting the heating mode, if you accidentally reverse the set temperature value, the output indicator will not light up, and the load will not work. After the setting is completed, if the above situation occurs, you can check whether the set temperature value is reversed.
list
1*Temperature Controller
Supply Voltage : 110V-220V
Model Number : Microcomputer temperature controller
Dissipation Power : 1500W
Operating Temperature : -50~110℃
Origin : Mainland China
Brand Name : Ziqqucu
Package : SOP
Application : Computer
Condition : New
Type : Voltage Regulator
is_customized : Yes